XL800 控制器 XCL8010A |
XCL8010A |
Excel 800 plant controller |
|
Panle I/O |
XF821A |
8 analog input module (Panel) |
XF822A |
8 analog output module (Panel) |
XFR822A |
8 analog output module with override (Panel) |
XF823A |
12 binary input module (Panel) |
XF824A |
6 relay output module (Panel) |
XFR824A |
6 relay output module with override (Panel) |
XFR825A |
Actuator output module with override (Panel) |
|
Lon I/O |
XFL821A |
8 analog input module (LON) |
XFL822A |
8 analog output module (LON) |
XFLR822A |
8 analog output module with override (LON) |
XFL823A |
12 binary input module (LON) |
XFL824A |
6 relay output module (LON) |
XFLR824A |
6 relay output module with override (LON) |
|
Terminal socket Model |
XS821-22 |
Terminal socket for analog input and output modules.The package includes 1 terminal socket, 1 connector bride and 1 swivel label. |
XS823 |
Terminal socket binary input modules.The package includes 1 terminal socket, 1 connector bride and 1 swivel label. |
XS824-25 |
Terminal socket relay output and floating output modules.The package includes 1 terminal socket, 1 connector bride, 1 cross connector and 1 swivel label. |
|
Accessary (Optional) |
XS812 |
Manual disconnector module for analog input, analog output and binary input. The manual disconnector is plugged betwE+En the terminal socket and the electronic module. It allows manual disconnection of individual signals. This is useful during start-up. |
XS812RO |
Manual disconnector module for relay output.The manual disconnector is plugged between the terminal socket and the electronic module. It allows manual disconnection of individual signals. This is useful during start-up. |
XS814 |
10 auxiliary terminal blocks. The auxiliary terminal block is used for distribution of signals. It includes 2 blocks with 7 terminals which are connected to each other. |
XS815 |
20 cross connectors (red in below figure) for connection of 6 relay commons.One cross connector is included in the terminal socket package. |
XS817 |
40 cross connectors (red in below figure) for connection of 3 relay commons (used if voltage on relay 1…3 is different to voltage on relay 4…5) |
XS816 |
10 bus bridges. One bus bridge is included in the terminal socket package. |
XAL10 |
10 swivel labels. The swivel label is used to attach the application specific label printed with CARE.One swivel label is included in the terminal socket package. |
XW882 |
XI582 cable for Excel 800 (a combination of XW586 and XW582 can be also used). |
XW885 |
Download cable for Excel 800 (a combination of XW586 and XW585 can be also used). |
XW884 |
Adapter cable to use XW882 and XW885 with an XL500 controller |
|
|